If the cord has printed on it ā250Vā and your mains power is between 220V-240V[1] and the power cable fits into your wall power outlet and into the amplifier, then go ahead and plug it in, you will have no problems. Can you plug a 240V appliance into a 250V outlet? The voltage listed is the maximum rated voltage that should be applied to it
\$\begingroup\$ I can't think of any reason why the cable itself shouldn't work. The plugs should also work fine, but it is a bit weird to have plugs and outlets designed for one voltage being used for another voltage. In some cases that could create some "gotcha" for an unsuspecting user if they plug something in to the wrong voltage
The original cord that plugs into my laptop power brick is rated 2.5A 125V. I've only been able to find a replacement cord online rated 2.5A 250V. Is it safe to use the 250V replacement even though the voltage is double? The brick input is 100-240V 1.6A 50/60Hz. Further detail, if needed, the brick output is 15.0Vā4.0A 60.0W, 5.0Vā1.0A 5.0W
Your NEMA 5-15 appliance is specifically designed to not plug into it. Because it would destroy the appliance if you did. That is why the system of plugs works like it does. Yours is a Taiwan derivative that does not allow multi-amperage, so it does not have the T-shaped L2 phase. Anything that plugs into the wall needs a specific voltage. The
The ratings on the plug refer just to the maximum capability of the plug. The ratings on the charger are what are important. Your charger is capable of working correctly from 100V to 240V, from 50Hz to 60Hz, and the maximum possible current it can take froms the mains supply is 1.6A. The charger will work OK from your 230V 50Hz supply.
The Utilization voltages are often a compromise. If I rate a motor at 230V, +- 10%, it can work on a 220V system as well as on a 250V system. The same is generally true for 3 phase commercial / industrial systems; 440-460-480 or 208-230-240 (although it can get more complicated by transformer configurations as well).
The IEC Type F plug has two 4.8 mm round pins, measuring 19 mm in length on centers spaced 19 mm apart. The distance between either of the two earthing clips and the middle of the imaginary line connecting the centers of the two power pins is 16 mm. Because the CEE 7/4 plug can be inserted in either direction into the receptacle, the Schuko
Check, and re-check that you have the neutral that belongs to this circuit or again, you risk putting 240V on a 120V circuit. Disconnect the hot (black) and remove the 1-pole breaker and remove the neutral (white) wire from the neutral buss bar. Install the new 2-pole breaker. Now you need to identify the white wire as a hot conductor.
.